Calibration and validation of the Mini-fiber EC image analysis instrument mean fiber diameter through direct or primary measurements

dc.contributor.authorFrank, Eduardo
dc.contributor.authorHick, E.N.
dc.contributor.authorCastillo, M.V.H
dc.contributor.authorGaut, M.C
dc.contributor.authorMamani Cato, Rubén Herberht
dc.coverage.spatialPerúes_PE
dc.date.accessioned2021-12-28T17:50:09Z
dc.date.available2021-12-28T17:50:09Z
dc.date.issued2021-12-13
dc.description.abstractThe Minifiber EC (MFEC) is a portable instrument for measuring the diameter of animal fibers. Its accuracy and precision have been estimated but by comparing its measurements with those of laboratory devices that had been calibrated on other devices in turn, not on a direct or primary measure of diameter. This work attempts to test direct measurements by gravimetry, Vernier mini caliper, microscope and the classic microprojector, using a non-deformable, high resistance synthetic fiber (Kevlar) for direct measurement. The MFEC instrument is calibrated with each mean fiber diameter obtained in direct measurements and its results are compared. The conclusions drawn are that it is possible to calibrate the MFEC instrument with direct measurements on Kevlar and measurement accuracy or tolerance of 0.28 microns is obtained. This indicates a very low biased mean fiber diameter measurement by MFEC.es_PE
dc.description.peer-reviewFrank E, Hick EN, Castillo MVH, et al. Calibration and validation of the mini-fiber EC image analysis instrument mean fiber diameter through direct or primary measurements. J Textile Eng Fashion Technol. 2021;7(6):209-217. doi: 10.15406/jteft.2021.07.00290es_PE
dc.description.tableofcontentsAbstract. Introduction. Materials & methods. Results. Discussion. Conclusion. References.es_PE
dc.formatapplication/pdfes_PE
dc.identifier.doihttps://doi.org/10.15406/jteft.2021.07.00290
dc.identifier.journalJournal of Textile Engineering & Fashion Technologyes_PE
dc.identifier.urihttps://hdl.handle.net/20.500.12955/1585
dc.language.isospaes_PE
dc.publisherMedCravees_PE
dc.publisher.countryArgentinaes_PE
dc.relation.ispartofJournal of Textile Engineering & Fashion Technology. 2021;7(6):209‒217.es_PE
dc.relation.publisherversionhttps://doi.org/10.15406/jteft.2021.07.00290es_PE
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/es_PE
dc.sourceInstituto Nacional de Innovación Agrariaes_PE
dc.source.uriRepositorio Institucional - INIAes_PE
dc.subjectMinifiber ECes_PE
dc.subjectMFECes_PE
dc.subjectDiameter of animal fiberses_PE
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#4.04.02es_PE
dc.titleCalibration and validation of the Mini-fiber EC image analysis instrument mean fiber diameter through direct or primary measurementses_PE
dc.typeinfo:eu-repo/semantics/articlees_PE

Archivos

Bloque original

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
Frank-et-al_2021_MEFC_Instrument.pdf
Tamaño:
647.62 KB
Formato:
Adobe Portable Document Format

Bloque de licencias

Mostrando 1 - 1 de 1
No hay miniatura disponible
Nombre:
license.txt
Tamaño:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descripción:

Sede Central: Av. La Molina 1981 - La Molina. Lima. Perú - 15024

Central telefónica (511) 240-2100 / 240-2350

FacebookLa ReferenciaEurocris
Correo: [email protected]

© Instituto Nacional de Innovación Agraria - INIA